We specialize in the production of funeral equipment, cremation machines, cremation furnaces, ice coffins, corpse refrigerators, and body handling equipment. Welcome to consult and customize!
Funeral equipment company manufacturer's phone number

current location:homepage > > Funeral equipment > Funeral refrigeration

Technical parameters of funeral parlor body farewell platform

Belonging category:Funeral refrigeration Publishing Date:20240114 views:2

1. Specification of farewell table: L5100*W4000*H1100(mm)


2. External material: titanium panel (thickness 1.0) mm.


3. Internal material: embossed aluminum plate (0.8 mm) specially used for freezer after oxidation and anticorrosion treatment.


4. Coffin cover: Double-layer PC transparent cover with a thickness of 4mm, which can bear 80Kg and has good daylighting.


5. Opening mode: fully automatic one-button remote opening with manual emergency button switch.


6. Surface material of catwalk: titanium gold panel (thickness 1.0mm)


7. Power-assisted guide wheel: industrial wear-resistant nylon wheel φ Φ30×30 (mm)


8. Decorative painting: 3D acrylic relief color printing is adopted, which has strong stereoscopic effect, waterproof and moisture-proof, and never fades.


9. Condenser: air-cooled finned copper coil condenser, with no solder joint design, ultra-quiet fan and anti-condensation treatment of coffin.


10. Thermal insulation layer: polyurethane foam with overall high-pressure temperature recovery (thickness 100 ㎜) with a density of 50kg/m3.


11. Rated temperature:-25 C


12. Input power: 478W*2


13. Power supply: 220V 50Hz


14. Unit form: totally enclosed compressors (2 sets)


15. Refrigerant: R404A


16. Temperature control: Microcomputer full-automatic temperature controller, which will give an audible and visual alarm prompt when it fails to reach the set temperature for a long time, and can set the temperature manually. When the voltage is unstable, the compressor can delay itself and protect itself. When the compressor is working, it can be defrosted by itself in different stages.


17, functional features:


1) If the microcomputer automatic rotating unit fails when the A unit is working, it will automatically rotate to work for the B unit, and it can work for both systems at the same time (strong cooling) or manually switch the AB unit to work in rotation, so as to ensure that the temperature in the cabinet is below minus 25 degrees, and avoid carrion and unnecessary disputes.


2) The rotating work of AB unit can be manually switched to prolong the service life of compressor.