We specialize in the production of funeral equipment, cremation machines, cremation furnaces, ice coffins, corpse refrigerators, and body handling equipment. Welcome to consult and customize!
Funeral equipment company manufacturer's phone number

current location:homepage > > Funeral equipment > Cremation equipment

Technical parameters of intelligent ash picking cremation furnace for funeral cremation

Belonging category:Cremation equipment Publishing Date:20240114 views:3

Technical parameters of intelligent ash-picking cremator


1. The external dimension of the furnace body: l * w * h = 3650× 2450× 3400 mm (2%). The external dimension of the furnace body can be adjusted according to the actual construction drawings of the workshop in the later period.


2. main furnace size: l * w * h ≥ 2300× 780× 700 mm (2%)


3. Furnace working pressure:-5 ~ -5~-30Pa


4. Continuous average cremation time: ≤45 minutes/set (continuous cremation of more than 3 sets)


5. Average fuel consumption for continuous cremation: ≤15 liters/set (more than 3 sets for continuous cremation)


6. Average cooling time: ≤ 15min/set


7. Fuel consumption for single cremation: ≤ 20l/set.


8. Fuel label: -10~0 light diesel oil


9. Smoke exhaust mode: lower smoke exhaust.


10. Daily maintenance requirements: The cremator shall meet the requirements of on-site maintenance and convenience, and the internal and external space shall meet the requirements of daily maintenance and operation, and meet the requirements of daily dust cleaning in flue and secondary combustion chamber.


11. Air distribution mode: it is controlled by the electric actuator of the bellows-type centralized air supply butterfly valve, with the function of manual and electric non-interference switching.


10. The cremator should have an automatic closed-loop control system for air supply based on the oxygen content as the control index, so as to ensure the optimal ratio of furnace temperature, blast, induced air and oxygen content in the main combustion chamber and reburning chamber of the cremator, and the workshop will be smoke-free, odorless and free of sparks during cremation.


11. Equipped with a reburning chamber.


12. The circuit design of the whole cremation machine system meets the standard of Code for Design of Distribution of General Electrical Equipment.


13. All major electrical components should have insulation grounding protection devices and measures. Under normal operating conditions, the main combustion chamber and reburning chamber should maintain a slight negative pressure, and no pollutants escape from the combustion chamber.


14. The cremation machine should have remote online guidance and real-time online monitoring system, and the parameters such as main furnace, reburning chamber, flue gas temperature, furnace pressure, oxygen content, fault diagnosis, abnormal working condition alarm and so on have the functions of data display, storage and return visit.


15. The cremation process is automatically controlled, displayed on the LCD touch screen, with a resolution of not less than 1024*768, and the keys have voice prompts, with stable operation and low failure rate.


16. Environmental protection effect: After the cremator is equipped with tail gas purification treatment equipment, the flue gas emission meets the requirements of the national standard GB13801-2015 Emission Standard for Air Pollutants in Crematorium.


17. The cremation process is automatically controlled, displayed on the LCD touch screen, with a resolution of not less than 1024*768, and the keys have voice prompts, with stable operation and low failure rate.


18. Environmental protection effect: After the cremator is equipped with tail gas purification treatment equipment, the flue gas emission meets the requirements of the national standard GB13801-2015 Emission Standard for Air Pollutants in Crematorium.


19. Service life: overhaul period is 5000 units or more than 3 years, and normal use is 10 years.