We specialize in the production of funeral equipment, cremation machines, cremation furnaces, ice coffins, corpse refrigerators, and body handling equipment. Welcome to consult and customize!
Funeral equipment company manufacturer's phone number

current location:homepage > > Funeral equipment > Cremation equipment

Technical parameters of flatbed crematoriums for epidemic prevention in funeral homes

Belonging category:Cremation equipment Publishing Date:20240114 views:3

1. External dimensions of the furnace body: l * w * h = 3650× 2450× 3400 mm (2%). The external dimensions of the furnace body can be adjusted according to the actual construction drawings of the workshop in the later period.


2. Furnace working pressure:-5-30pa.


3. Main furnace size: L * W * H ≥ 2300 * 780 * 700 mm (2%).


4. Environmental conditions for normal use of equipment: -20℃-+40℃, below 5000m above sea level.


5, continuous average cremation time is less than or equal to 50 minutes/set (continuous cremation of more than 3 sets)


6. Average fuel consumption for continuous cremation: ≤ 20l/set (more than 3 sets for continuous cremation).


7. Fuel label: -10~0 light diesel oil


8. Smoke exhaust mode: lower smoke exhaust.


9, equipped with a combustion chamber, should be equipped with high-quality automatic burner, burner can automatically adjust the flame size, ignition failure should be able to automatically turn off the fuel supply.


10. Air distribution mode: it is controlled by the electric actuator of the bellows-type centralized air supply butterfly valve, with the function of manual and electric non-interference switching.


11. The cremator should have an automatic closed-loop control system with oxygen content as the control basis, so as to ensure the optimal ratio of furnace temperature, blast, induced air and oxygen content in the main combustion chamber and reburning chamber of the cremator, and the workshop will be smoke-free, odorless and free of sparks during cremation.


12. The circuit design of the whole cremation machine system meets the standard of Code for Design of Distribution of General Electrical Equipment.


13, the main electrical components should have insulation grounding protection devices and measures, under normal operating conditions, the main combustion chamber and reburning chamber should be kept slightly negative pressure, no pollutants escape from the combustion chamber.


14. The cremation process is automatically controlled, displayed on the LCD touch screen, with a resolution of not less than 1024*768, and the keys have voice prompts, with stable operation and low failure rate.


15. Environmental protection effect: After the cremator is equipped with tail gas purification treatment equipment, the flue gas emission meets the requirements of the national standard GB13801-2015 Emission Standard for Air Pollutants in Crematorium.


16. Service life: overhaul period is 5000 units or more than 3 years, and normal use is 10 years.